- Products
- RTU Hardware
- MyDro 50
MyDro 50 Remote Terminal Unit
The MyDro 50 is a compact, battery-powered remote terminal unit that eliminates monitoring blind spots across your water system. With a battery life of up to five years, three analog inputs, three digital inputs, and a latching relay output, the MyDro 50 delivers critical data and control capabilities from sites that have no AC power, no wired network infrastructure, and no budget for a full-scale RTU installation.

- Power
- Battery · up to 5 years
- Onboard I/O
- 3 analog · 3 digital · 1 relay
- Cellular
- LTE CAT M1 / NB-IoT
- Form factors
- Wall Mount · Node · Rainfall
Works Where the Power Grid Doesn’t
The MyDro 50 is powered by a four D-cell lithium thionyl chloride battery pack rated at 76 amp-hours. Depending on transmission frequency and sensor configuration, the battery can last up to five years before replacement.
The RTU uses LTE CAT M1 / NB-IoT with auto-selectable power saving features via eDRX to maximize battery life while maintaining reliable cellular connectivity.

Applications
Four ways utilities put the MyDro 50 to work at sites that have no AC power.
Water Flow Monitoring
Works with the flow meters you already have, accepting pulse or analog (4-20 mA or 0-5V) inputs. Pulse counts and analog flow rates are converted to total volume and reported in selectable time blocks (hourly, daily, and more), with daily totals and usage trends calculated for you. High, low, and daily-limit flow alarms flag problems early, and reports are ready to download, including flow against rainfall.
Tank and Well
The MyDro 50 is an ideal component for Mission’s Tank and Well application. It can monitor any type of tank level and deliver essential data to the Tank and Well service for automated pump cycle control. The MyDro 50 is especially well-suited for single-pump wells, providing one runtime input and one status input to reduce the overall cost of well field control systems.
Reservoir and Surface Level Monitoring
Monitor levels of reservoirs, lakes, rivers, and other surface waters with compatibility for a variety of sensors including submersible and non-contact types. Historical data and real-time alarms provide complete visibility into water supply conditions.
PRV Vault Monitoring
Pressure reducing valves (PRVs) protect water infrastructure by preventing pipe damage and maintaining consistent system pressure. The MyDro 50 can power and monitor two pressure sensors, one upstream and one downstream of the PRV, for continuous visibility into inlet and outlet pressure. Through 123SCADA, utilities can spot abnormal pressure and potential valve issues before they lead to failures.
Three Form Factors
Wall Mount
The Wall Mount form factor features an industrial polycarbonate UV-rated enclosure with IP68 ingress protection. It mounts directly to a wall, pole, or structure near the monitoring point. Weight with battery: 2 lbs, 15 oz. The M52 is ideal for pump houses, valve vaults, and above-ground equipment enclosures where environmental sealing is critical.
Node
The Node form factor uses an industrial polycarbonate UV-rated enclosure with IP67 ingress protection and a compact cylindrical design optimized for pole or mast mounting. Weight with battery: 2 lbs. The M54 is well-suited for tank sites, reservoir monitoring, and remote locations where a small visual footprint is preferred.
Rainfall Monitoring
The Rainfall Monitoring model is a purpose-built package that includes the MyDro 54R RTU, a rain tipping bucket with cable, mounting plate with screws, U-clamp and mounting bracket, and base stand. The M54R requires no grid power or network wire, providing long-term rain totals and live monitoring of rain intensity. It connects directly to the 123SCADA portal for storm event analysis and I&I correlation. Enclosure rated IP67; dimensions 7.1 in height x 4.6 in diameter; weight 2 lbs.
I/O Capabilities
- 3 analog inputs (passive or active): 4-20 mA or 0-5V; 13V or 18V provided to attached sensors at up to 60 mA
- 3 digital inputs: dry contact, reporting state and total counts
- 1 latching relay output: 2A at 30VDC for remote control applications
- Tank and Well: 1 runtime and 1 status available for automated pump cycle control
- Flow measurement: Totalized from pulse inputs or analog integrated flow calculation

Technical Specifications
- Battery
- Four D-cell lithium thionyl chloride, 76 AHr; up to 5-year life
- Cellular
- LTE CAT M1 / NB-IoT, auto-selectable; SparkPlug messaging; PTCRB certified
- Radio Power
- 23 dBm with internal GPS antenna
- Safety Rating
- Class 1 Division 2 Certified, Groups A, B, C, D; Temperature Code T5; CSA, UL, CE approved
- Operating Temperature
- -40 to +185°F (-40 to +85°C)
- Humidity
- 0% to 100% condensing
- Electrical Connection
- Pluggable terminal block, 16-30 AWG screw terminals
- SIM
- Included; power saving via eDRX

MyDro 850
The full-featured, line-powered RTU with the most extensive I/O capacity. Ideal for larger stations requiring multiple analog and digital inputs, relay outputs for remote control, and expansion module support.
View MyDro 850
MyDro 150
A compact, line-powered RTU that delivers core monitoring and alarm capabilities in a smaller form factor. Supports emergency backup pump control and is upgradeable to the M850’s feature set.
View MyDro 150
MyLevel
Battery-powered ultrasonic manhole monitor for CSO/SSO applications. Installs below grade and provides reliable level monitoring, real-time alarms, and years of operation on a single battery.
View MyLevelFrequently Asked Questions
Why is the Mydro 50 a good fit for remote locations?
The Mydro 50 is a good fit for remote locations because it is designed for straightforward deployment where compact hardware and reliable monitoring are important. That makes it useful for smaller or more isolated assets.
What types of sites can use the Mydro 50?
The Mydro 50 can be used on sites such as tanks, pump locations, and other remote assets that benefit from simple monitoring and alerting. It is especially useful where a compact RTU is preferred.
How does battery-powered telemetry help with deployment?
Battery-powered telemetry can make deployment easier where power access is limited or installation simplicity matters. It helps reduce site constraints and supports monitoring in harder-to-reach locations.
Get Started
Not sure which solution fits? Tell us about your system — we’ll recommend the right hardware, monitoring, and reporting for your utility