MyDro 850 Remote Terminal Unit

The MyDro 850 is Mission Communications’ most advanced remote terminal unit, purpose-built for master pump stations, critical process monitoring, and complex multi-point control applications. It delivers real-time alarm data and streaming analog values reported every two minutes or on 5% change, providing the continuous visibility that high-priority infrastructure demands.

MyDro 850 RTU installed at a pump station
Reporting
Every 2 min or on 5% change
Onboard I/O
8 digital · 2 analog · 3 relay
Cellular
Multi-carrier 4G LTE CAT. 1
Backup
Up to 18 hours battery
Why it is different

Real-Time Streaming Data

Unlike RTUs that report on fixed intervals, the MyDro 850 streams analog data in near real-time. Analog values are reported every two minutes or whenever a 5% change is detected, whichever comes first.

This streaming approach captures rapid fluctuations in levels, pressures, and flows that interval-based reporting would miss. Pump states are reported in real-time with support for up to eight configurable pump runs and simultaneous runtime tracking for up to seven pumps.

123SCADA live data analytics trend for a MyDro 850
Inputs and outputs

I/O Capabilities

The MyDro 850 delivers extensive input/output capacity out of the box, with expansion options to scale for the most demanding installations:

  • 8 onboard digital inputs with selectable wire fault supervision or direct attach current sensing switch; expandable to 16 with PN OP653 expansion module
  • 2 onboard analog inputs (4-20 mA isolated or 0-5 VDC) with 4 alarm set points each; expandable to 9 with PN OP465 module
  • 3 remotely controllable relay outputs (Form C, dry contact, 5A at 30VDC, SPDT, N/O or N/C); expandable to 9 with PN OP654 module
  • 4 pulse input channels with Safe Module Plus expansion module (PN OP750) with 2-minute reporting
  • 4 analog output channels (4-20 mA) with PN OP461 module
  • RS485 support for specified expansion modules
  • Electronic key reader for site activity tracking and service mode
MyDro 850 input/output terminals
Built-in automation

Automated Control Features

The MyDro 850 supports advanced automated control capabilities that eliminate the need for separate PLCs or radio networks:

Automated control features diagram

Digital Interconnect

A digital input/output change at one RTU automatically triggers a relay change at another RTU. Automate site-to-site control without private radio networks.

Analog Interconnect

Mirror analog values between locations in real-time for coordinated process control.

Tank and Well Control

Automatically command well pumps on and off based on tank level readings. Supports up to five outputs (pumps, valves, etc.).

Emergency Backup Pump Control

Software-enabled feature that temporarily takes over pump control for up to two pumps when the primary controller fails.

See it on lift stations
Where it fits

Applications

Wastewater Applications

  • Master pump station monitoring and remote control
  • Critical process monitoring with real-time streaming data
  • Open channel flow monitoring and measurement
  • Sewer station power monitoring and alarming
  • Reuse water monitoring and control

Water Applications

  • Pump station monitoring with multi-pump runtime tracking
  • Tank and multiple well monitoring and automated control
  • Remote valve monitoring and control
  • Chlorine (Cl) residual water quality alarming
  • Flow and pressure monitoring with volumetric calculations
Hardware

Enclosure Options

PN M853

FlatPak

Compact, low-profile enclosure — 10.5 x 7.75 x 1.5 in, 1.8 lbs

PN M851

NEMA 1

Indoor wall mount — 11.375 x 11.25 x 3.5 in, 3.6 lbs

PN M852

NEMA 4X

Outdoor rated with sun shield — 13.25 x 13.75 x 6.25 in, 7.6 lbs

PN M852L

Large NEMA 4X

For installations requiring additional space for expansion modules

Specifications

Technical Specifications

AC PowerSupervised 120 VAC to 12 VAC, 1.2A, UL-recognized Class II/Class III transformer
Backup Battery12V, 5Ah standard with enhanced charging system; up to 18 hours backup
Auxiliary OutputSelectable 12 VDC or 24 VDC for battery-backed analog instrument loop powering; 250 mA max
Power Consumption4.2W
Cellular RadioMulti-carrier embedded SIM (AT&T, T-Mobile, Verizon, Telenor); 4G LTE CAT. 1 Radio make live, continuous, encrypted TCP socket connections; Payload is end–to–end acknowledged.
LCD Touch ScreenDisplays current status and supports local configuration
EnvironmentOperating temperature -20 to 60°C, non-condensing
WarrantyTwo-year manufacturing and material warranty
Water Systems Monitoring

Need the data sheet or install guide?

Documentation and install guides for every MyDro RTU are in the Technical Library.

Common questions

Frequently Asked Questions

What kind of applications is the Mydro 850 built for?

The Mydro 850 is suited for monitoring applications that need strong performance, reliable communications, and more advanced capability in the field. It is a fit for systems where higher demand or more complex monitoring is involved.

How does the Mydro 850 support remote monitoring?

It supports remote monitoring by collecting site data, sending alerts, and integrating with the Mission’s 123SCADA platform for visibility and control. That helps users manage important assets without needing to stay on site.

Why would a utility choose the Mydro 850 over another RTU?

A utility may choose the Mydro 850 when it needs more capability, stronger performance, or a product designed for more demanding monitoring environments. The choice depends on site requirements and operational goals.